Home / Products / Transformers / Encapsulated PCB Mount / UI30
UI 30 - Low Profile Encapsulated PCB Mount Transformer - 3-10VA
3–10 VA · 50/60Hz
A high-quality series of Low Profile safety transformers.
Product description
A high-quality series of Low Profile safety transformers.
The Low Profile series is ideal for applications with component height restrictions such as where a close spacing between boards is needed.
Typical design is with 2x115V primary for 115V or 230V input at 50/60Hz and dual secondary with two identical output voltages.



View from PCB
Solder pins 0.8 mm Ø
Grid 5 mm
UI30-0./.../... · One chamber bobbin
UI30-1./.../... · Two chamber bobbin
Dual output connectionsStandard types
| Type | Single output |
Dual output |
Ambient temp. |
VDE |
* | Stack height mm | Case height [H] mm | Weight g |
|---|---|---|---|---|---|---|---|---|
| UI30-.1/7.../... | 6...30V - 3.00 VA | 2x6...15V - 2x1.50 VA | 70°C/B | X | ukf | 5.5 | 17.1 | 127 |
| UI30-.2A/7.../... | 6...32V - 4.00 VA | 2x6...16V - 2x2.00 VA | 70°C/B | X | nkf | 7.5 | 19.1 | 150 |
| UI30-.2F/7.../... | 6...32V - 4.00 VA | 2x6...16V - 2x2.00 VA | 70°C/B | X | bkf | 7.5 | 19.1 | 150 |
| UI30-.3G/7.../... | 6...34V - 6.00 VA | 2x6...17V - 2x3.00 VA | 70°C/B | X | nkf | 10.5 | 22.6 | 187 |
| UI30-.3F/7.../... | 6...34V - 6.00 VA | 2x6...17V - 2x3.00 VA | 70°C/B | X | bkf | 10.5 | 22.6 | 187 |
| UI30-.4G/7.../... | 6...36V - 10.00 VA | 2x6...18V - 2x5.00 VA | 70°C/B | X | nkf | 16.5 | 28.5 | 260 |
| UI30-.4F/7.../... | 6...36V - 10.00 VA | 2x6...18V - 2x5.00 VA | 70°C/B | X | bkf | 16,5 | 28.5 | 260 |
Standards and construction
- Approved according to EN 61558. VDE 0570
- Vacuum cast
- Safety class II
- Protective system IP 00
- Absolutely short circuit proof (*ukf). or conditionally short-circuit proof (*bkf) through built-in temperature fuse, or not short-circuit proof (*nkf) but protected by external fuse on primary or secondary
Note: If using conditionally short-circuit proof transformer type (*bkf) or internally connected (UI30-1./.../...) transformer type, no strip conductors may be guided between the primary connecting pins on the component insertion side, because in this area there is an unprotected live soldering terminal.
Variants available on request
Ambient temp.
VDE