Home / Products / Transformers 50/60Hz / Encapsulated PCB Mount
EI60 — Encapsulated PCB Mount Transformer — 20–43.5 VA
| A series of EI60 safety transformers for PCB mounting. High-quality encapsulated vacuum potted transformers. |
![]() |
Product description and technical data
Our comprehensive selection of products also includes a series of EI60 safety transformers for PCB mounting.
High-quality encapsulated vacuum potted transformers. Output power from 20VA.
High-quality encapsulated vacuum potted transformers. Output power from 20VA.
![]() |
![]() |
![]() |
| View from PCB | Solder pins 0.8 mm Ø |
- Grid 5 mm |
| Type | ![]() |
![]() |
![]() |
* | Stack Height mm |
Case Height (H) mm |
Weight g |
| EI60-12A/7.../... | 70°C/B | 6...40V - 20,00 VA | 2x6...20V - 2x10,00 VA | nkf | 21,0 | 46,8 | 565 |
| EI60-12F/7.../... | 70°C/B | 6...40V - 23,50 VA | 2x6...20V - 2x11,75 VA | bkf | 21,0 | 46,8 | 565 |
| EI60-12A/4.../... | 40°C/B | 6...40V - 24,00 VA | 2x6...20V - 2x12,00 VA | nkf | 21,0 | 46,8 | 565 |
| EI60-12F/4.../... | 40°C/B | 6...40V - 30,00 VA | 2x6...20V - 2x15,00 VA | bkf | 21,0 | 46,8 | 565 |
| EI60-32A/7.../... | 70°C/B | 6...40V - 25,00 VA | 2x6...20V - 2x12,50 VA | nkf | 25,5 | 50,0 | 687 |
| EI60-32F/7.../... | 70°C/B | 6...40V - 26,50 VA | 2x6...20V - 2x13,25 VA | bkf | 25,5 | 50,0 | 687 |
| EI60-32A/4.../... | 40°C/B | 6...40V - 28,50 VA | 2x6...20V - 2x14,25 VA | nkf | 25,5 | 50,0 | 687 |
| EI60-32F/4.../... | 40°C/B | 6...40V - 34,00 VA | 2x6...20V - 2x17,00 VA | bkf | 25,5 | 50,0 | 687 |
| EI60-34A/7.../... | 70°C/B | 6...40V - 31,00 VA | 2x6...20V - 2x15,50 VA | nkf | 30,5 | 55,0 | 785 |
| EI60-34F/7.../... | 70°C/B | 6...40V - 31,00 VA | 2x3...20V - 2x15,50 VA | bkf | 30,5 | 55,0 | 785 |
| EI60-34A/7.../... | 40°C/B | 6...40V - 37,00 VA | 2x6...20V - 2x18,50 VA | nkf | 30,5 | 55,0 | 785 |
| EI60-34F/4.../... | 40°C/B | 6...40V - 43,50 VA | 2x6...20V - 2x21,75 VA | bkf | 30,5 | 55,0 | 785 |
- Approved to EN 60742
- Vacuum cast
- Two chamber coil
- Safety class II
- Protective system IP 00
- Conditionally short-circuit proof (*bkf) through built-in temperature fuse,
or not shorts-circuits proof (*nkf) but protected by external fuse on primary or secondary
Variants available on request
50/60Hz transformer. See the source technical table above for standard types and specifications.