Home / Products / Transformers 50/60Hz / Encapsulated PCB Mount
EI54 — Encapsulated PCB Mount Transformer — 13.5–25 VA
| A series of EI54 safety transformers for PCB mounting. High-quality encapsulated vacuum potted transformers. |
![]() |
Product description and technical data
Our comprehensive selection of products also includes a series of EI54 safety transformers for PCB mounting.
High-quality encapsulated vacuum potted transformers. Output power from 13.5VA.
Note: If using the conditionally short-circuit proof transformer type(*bkf), no strip conductors may be guided between the primary connecting pins on the component insertion side, because in this area there is an unprotected live soldering terminal.
#top#
High-quality encapsulated vacuum potted transformers. Output power from 13.5VA.
![]() |
![]() |
![]() |
||||
| View from PCB | Solder pins 0,8 mm Ø | - Grid 5 mm | ||||
| Type | ![]() |
![]() |
![]() |
![]() |
* | Stack Height mm |
Case Height (H) mm |
Weight g |
| EI54-12E/7.../... | 70°C/B | 6...40V - 13.50 VA | 2x6...20V - 2x 6.75 VA | x | nkf | 18.8 | 39.0 | 410 |
| EI54-12A/7.../... | 70°C/B | 6...40V - 15.00 VA | 2x6...20V - 2x 7.50 VA | x | nkf | 18.8 | 39.0 | 410 |
| EI54-12F/7.../... | 70°C/B | 6...40V - 16.00 VA | 2x6...20V - 2x 8.00 VA | x | bkf | 18.8 | 39.0 | 410 |
| EI54-32A/7.../... | 70°C/B | 6...39V - 19.00 VA | 2x6...19V - 2x 9.50 VA | x | nkf | 23.0 | 43.5 | 500 |
| EI54-32F/7.../... | 70°C/B | 6...39V - 20.50 VA | 2x6...19V - 2x10.25 VA | x | bkf | 23.0 | 43.5 | 500 |
| EI54-32A/4.../... | 40°C/B | 6...36V - 21.00 VA | 2x6...18V - 2x10.50 VA | x | nkf | 23.0 | 43.5 | 500 |
| EI54-32F/4.../... | 40°C/B | 6...36V - 25.00 VA | 2x6...18V - 2x12.50 VA | x | bkf | 23.0 | 43.5 | 500 |
- Approved to EN 60742
- Vacuum cast
- Two chamber coil
- Safety class II
- Protective system IP 00
- Conditionally short-circuit proof (*bkf) through built-in temperature fuse.
or not short-circuits proof (*nkf)
Note: If using the conditionally short-circuit proof transformer type(*bkf), no strip conductors may be guided between the primary connecting pins on the component insertion side, because in this area there is an unprotected live soldering terminal.
Variants available on request
#top#
50/60Hz transformer. See the source technical table above for standard types and specifications.