Home / Products / Transformers / EI30

EI30 – Encapsulated PCB Mount Transformer

50/60Hz · 0.6–4.8VA

A series of EI30 safety transformers for PCB mounting. High-quality encapsulated vacuum potted short-circuit proof transformers.

Product description

Our comprehensive selection of products also includes a series of EI30 safety transformers for PCB mounting.

High-quality encapsulated vacuum potted short-circuit proof transformers. Output power from 0.6VA.

Print layout – EI30 transformer
Pin and transformer height
EI30 encapsulated transformer
View from PCB
Solder pins 0.8 mm Ø
Grid 5 mm

Standard types

Type Maximum ambient temperatureAmbient temp. Single output connectionsSingle output Dual output connectionsDual output VDE markingVDE UL markingUL *Stack height
mm
Case height
mm
Weight
g
EI30-X10/7.../..70°C/B6...24V - 0.70 VA2x6...12V - 2x0.30 VAxxukf5.015.544
EI30-X6/7.../...70°C/B6...28V - 1.50 VA2x6...14V - 2x0.65 VAxxukf10.523.075
EI30-X6/4.../...40°C/B6...26V - 1.70 VA2x6...13V - 2x0.75 VAx—ukf10.523.075
EI30-Y7/7.../...70°C/B6...29V - 1.70 VA2x6...14V - 2x0.75 VAxxukf12.524.785
EI30-Y7/4.../...40°C/B6...27V - 2.00 VA2x6...13V - 2x0.90 VAx—ukf12.524.785
EI30-Y8/7.../...70°C/B6...28V - 2.00 VA2x6...14V - 2x0.90 VAxxukf15.027.398
EI30-Y8/4.../...40°C/B6...27V - 2.40 VA2x6...13V - 2x1.10 VAx—ukf15.027.398
EI30-Y8F/7.../...70°C/B6...32V - 2.40 VA2x6...16V - 2x1.10 VAxxukf15.027.398
EI30-Y9/7.../...70°C/B6...28V - 2.30 VA2x6...14V - 2x1.00 VAxxukf18.030.2117
EI30-Y9F/7.../...70°C/B6...30V - 2.70 VA2x3...15V - 2x1.25 VAxxukf18.030.2117
EI30-Y9/4.../...40°C/B6...28V - 2.80 VA2x6...14V - 2x1.30 VAx—ukf18.030.2117
EI30-Y10/7.../...70°C/B6...30V - 2.80 VA2x6...15V - 2x1.40 VAx*—ukf23.034.4140
EI30-Y10/4.../...40°C/B6...28V - 3.60 VA2x6...14V - 2x1.80 VA——ukf23.034.4140
EI30-Y10F/7.../...70°C/B6...32V - 4.00 VA2x6...16V - 2x1.80 VA——bkf23.034.4140
EI30-Y10F/4.../...40°C/B6...30V - 4.80 VA2x6...15V - 2x2.20 VA——bkf23.034.4140

Standards and construction

  • Approved to EN 61558, UL 506 UL 1585 CI.2 and C1.3, C22.2
  • Vacuum cast
  • Two chamber coil
  • Safety class II
  • Protective system IP 00
  • Absolutely short circuit proof (*ukf), or conditionally short circuit proof (*bkf) through temperature fuse
Note: If using conditionally short circuit proof transformer type (*bkf), no strip conductors may be guided between the primary connecting pins on the component side, because in this area there is an unprotected live soldering terminal.

Variants available upon request