LTM-110A - Line Interface 56kbps Modem Transformer

The LTM 110A Line Interface 56kbps Modem Transformers are designed for V.90 applications. They meet IEC60950 Supplementary Isolation levels and are of excellent quality at competitive price due to high volume production.   LTM-110A - Line Interface Modem Transformer

Product information and technical data


Features

  • designed for V.90 applications (56kbps)
  • very low distortion
  • wide frequency range with flat response
  • meets IEC 60950 Supplementary Insulation levels, 1,500V min.
  • excellent quality at competitive price due to high volume production
  • manufactured in ISO-9001:2000 approved facility
  LTM-110A - Line Interface Modem Transformer
 


Mechanical Dimensions & Pinout
Performance Date

Electrical Specifications @ 25°C - Operating Temperature -40°to 85°C

Parameter Conditions Typical Limit Units
 Frequency Response 200 - 4,000Hz ±0.5 - dB
 Insertion Loss 2,000Hz, RL600 Ohms 1.0 1.5 max dB
 Return Loss 200 - 4,000Hz 22 18 min. dB
 THD 150Hz, -3dBm -70 - dB
 THD 200Hz, -10dBm -85 - dB
 DC Resistance per winding 70 ±10% Ohms
 Inductance 1,000Hz, 1V 6.0 - H
 Leakage Inductance 1,000Hz, 1V 17 - mH
 Turns Ratio
1:1 ±2% -

#top#

Mechanical Dimensions, Pinout & Schematic

Dimensions & Schematic - Pins

Perfomance Data
#top#